MCA(DN) Series End Suction Pumps are booster pumps which comply with DIN24255 (EN733) standard. Pumps range in size from 32-125 to 300-400. Typical applications include circulation of liquids, condenser water, heating water, irrigation and HVAC.
Featured: DN Series-Bare Shaft Pumps
Design Features:
- The DN range of pumps complies fully to the international standard DIN24255. This standard covers both performance and dimensions.
- This pump includes the back pull-out design, and when a suitable spacer coupling is fitted to a direct coupled unit, the casing and motor can remain in position while all other pump parts can be removed for simple and quick maintenance.
- The volute casing is fitted with a replaceable wear ring and has a suction vane to give smooth flow into the double shrouded hydraulically balanced impeller.
- Only three shaft assemblies are required to cover the total range , and this gives many common interchangeable parts for pumps fitted to the same shaft.
- Standard pump is fitted with a packed stuffing box incorporating a lantern ring which includes internal flushing by the liquid being pumps, or can be converted to external flushing, and all of these pumps can be fitted with a mechanical seal.
- Pumps can be supplied as a bare shaft united, or in many other arrangements, including complete with coupling, guard, base plate and either electric motor or engine.
MAXIMUM TEMPERATURE
- With standard packed gland-minus 10oC to 5oC.
- Maximum with cooled stuffing box-160oC
- With mechanical seal-maximum depends upon seal used.
MAXIMUM PRESSURE
- Maximum Operating pressure: 1600KPa
- Maximum test pressure: up to 2100KPa
- Maximum pressure will vary depending on particular pump model
- higher rating available on application
MAXIMUM SPEED
Maximum direct coupled speed four pumps varies between 3600RPM and 1800RPM depending upon pump size and method of drive.
ADDITIONAL INFORMATION
- Cast Iron casing with integrally cast feet
- Back-pullout facility permits removal of back cover, stuffing box and impeller without disturbance of suction and delivery pipe woke. Drive motor can also remain in place if a spacer coupling is fitted.
- Shaft carried in grease lubricated bearings
- Just three shaft modules cover the entire range and all pumps common to one shaft module have identical bearing, shaft sleeve, seals, and impeller fastenings.
- Cast iron bearing housing secured to cover plate and volute. Only three sizes cover the entire range.
- Shaft sealing by soft packed gland with stainless steel shaft sleeve. Alternatively, by mechanical seals.
- For liquid temperatures over 105oC and up to 160oC, a gland cooling chamber can be formed by the addition of a cover plate.
- Double shrouded design of impeller with back balancing vanes or, on larger diameters, hydraulically balanced by incorporating.
- Replaceable wear rings fitted to all volutes and also to back covers of larger pumps.
APPLICATIONS
- Circulation of Liquids
- Condenser Water
- Heating Water
- Irrigation
- HVAC
Material Options
|
CODE |
CASING |
IMPELLER |
SHAFT |
SLEEVE |
WEAR RING |
|
2 |
Cast Iron |
Bronze |
Stainless Steel |
Stainless Steel |
Cast Iron |
|
1 |
Cast Iron |
Cast Iron |
Stainless Steel |
Stainless Steel |
Cast Iron |